XchangeR Basement Fan
Ventilate Smelly, Musty Basements
Many homes have basements that are stale musty or smelly because of seasonal
water issues, sump pits, floor drains or general lack of air exchange. The
XchangeR Basement Fan is the economical and simple way to automatically
ventilate your basement to eliminate odors and reduce humidity.
|
Features: Adjustable dehumidistat and
separate on/off switches for each of the quiet 90 CFM fans
Built in dampers with settable stop to prevent unwanted air from
entering your home
Simple plug-in electrical (6' cords) and vary low power use
Installs through rim joist of 16" on center or greater floor joists
Available plug-in speed control (Model SCP)
Available ducting kit with 6" diffusers/intakes
For less than the cost of a portable dehumidifier and at a fraction
of the operating expense, reduce humidity levels and eliminate the musty
smell in your basement by installing a Tjernlund XchangeR basement fan. |
Easily flip ONE or BOTH fans to have them*:
Exhaust musty air or air contaminated by
wood off-gassing or radon
Supply fresh make up air in tight homes or for stoves and
fireplaces
Position one fan in each direction for balanced
fresh air exchange
* All three orientations exceed ASHRAE 62.2-2007 Ventilation Air
Requirements |
Specifications
Number of Fans Operating |
Voltage |
Watts |
Amps |
CFM |
1 |
120 VAC |
36 |
0.3 |
90 |
2 |
120 VAC |
72 |
0.6 |
180 |
Click
on the video to watch the |
|
XchangeR Basement Fan in action. |
|
|
Accessories
DT2-6 Dual
Pipe Adaptor
Use the DT2-6 kit so exhaust can be
removed from outside the mechanical room if necessary. The DT2-6 can
also be used to duct outside supply air to a room where the XCHANGER™
is not installed in. (Flex duct not included). |
SCP Speed
Control
Use to turn inline fans on/off and to vary motor RPM. Plug fan
cord directly into speed control and speed control directly into outlet.
|
|
SCP Instructions |
XCHANGERTM DT2-6 6” DUCT TAKE OFF KIT
WARNING: Sufficient air is needed for proper combustion and exhausting of gases
through the flue (chimney) of fuel burning equipment
to prevent backdrafting. Follow the heating equipment manufacturer’s guideline
and safety standards such as those
published by the National Fire Protection Association (NFPA), and the American
Society for Heating, Refrigeration and
Air Conditioning Engineers (ASHRAE), and the local code authorities.
WARNING: Do not exhaust air from mechanical room unless makeup air is also
supplied or equipment in mechanical room is sealed
combustion. Carbon monoxide poisoning may result. Use the DT2-6 kit so exhaust
can be removed from outside the mechanical
room if necessary. The DT2-6 can also be used to duct air to a room where the
XCHANGERTM is not installed in.
Disconnect power supply to fans and/or control when installing the DT2-6.
Failure to do so may result in personal injury and/or equipment damage.